BOECO Clinical Photometer PM-51
BOECO Clinical Photometer PM-51

as

BOECO photometer PM-51, with integrated printer, flow-through cell, standard cuvette adapter and filter wheel (340, 405, 492, 546, 578, 623 nm), 90-264 V, 50/60 Hz.

  • Semi-automated photometric system.
  • Effective temperature regulation system.
  • Flexible cuvette concept, interchangeable flow-through or standard cuvette.
  • Reagent-open system with high capacity for programmable methods.
  • Teach-in capability for reagent application via touchscreen.
  • Minimum sipping volume 250 µL.
  • Double-secured liquid control with infrared bubble detector.
  • Future-proof operation, can easily be upgraded.

 

Discover more products to suit your laboratory needs from Boeco Product Guide here.

 

Download PDF:

PM-51

Type Semi-automatic, single-beam filter photometer
Light Source Halogen lamp – 12 V, 20 W with protection for lifetime
Wavelength 340 nm – 800 nm
Wavelength Selection Automatic via 9-position filter wheel : 6 standard interference filters: 340, 405, 492, 546, 578, 623, 3 positions for optional filter of choice
Photometric Range 0 – 2.5 Bel
Cuvette System Microflow cell: 32 µl, 10 mm light path interchangeable with normal standard cuvettes (macro or semi-micro, disposable or special optical glass) Temperature Control Internal Peltier element, temperature variable, pre-adjusted to 25 °C, 30 °C and 37 °C Equilibration time for aspirated reaction mixture to reach 37 °C from ambient temperature: 15 sec
Aspiration System Built-in peristaltic pump driven by stepper motor programmable aspiration volume controlled by infrared light barrier
Sipping Volume Minimum 250 µL, typically 500 µL up to 2000 µL Separate setting of aspirate volume and wash volume
Operator interface Touchscreen, for direct functions and alphanumeric inputs
Data Presentation Graphic display, White characters or symbols, blue background, lighted, resolution 240 x 126 dots.
Integrated Printer Thermal printer, 24 characters per line
Languages English, German, Spanish, French and Russian General operating software can be updated by PC Reagent open system with capacity for up to 231 programmable methods Import of data by touchscreen or PC Up to 50 non-linear calibration curves with max 20 sets of points can be stored
Data Logging Up to 1000 results can be saved in memory automatically
Signal Port 1 serial port for connection to an external printer or PC (bidirectional interface)
Measurement Procedures – Absorbance
– Endpoint with standard, factor or multiple standards, with or without reagent blank and/or sample blank
– Bichromatic end point
– Kinetics with standard, factor or multiple standards, with or without blank
– Fixed time with standard, factor or multiple standards, with or without reagent blank
– Turbidimetry with optional timer function
– Single, double and triple determinations
– Curve fitting for non-linear standard curves
– Free hemoglobin in combination with optional interference filters
Measuring Time Kinetic: variable from 3 – 19 deltas, time per delta 4 – 255 sec. Fixed time: variable from 0 – 65535 sec.
Delay Time Programmable from 0 – 65535 sec.
Mains Supply Range 100 Vac up to 240 Vac at 50/60 Hz
Dimensions in cm (LxWxH) 33×34 x18
Weight 5.3 kg